Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 29

TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-26
August 9, 2005
Ka a a
w s k
⇒
Reteach program steps to eliminate sudden high speed direction changes (dynamic
shock).
⇒
Ensure cooling fans are in proper working condition.
⇒
Reduce controller ambient temperature.
⇒
Replace defective thermal switch(es).
⇒
Repair or replace disconnected or defective harness(es).
⇒
Replace the regenerative unit.
⇒
Replace the 1KB board, power block or harness.
⇒
Replace the additional regenerative resistor unit.
⇒
Connect or repair D7X power supply connection for heat exchange fan (X207).
_____________________________________________________________________
ERROR CODE D1011
AS or servo software is not compatible with the robot
model.
This error occurs when the servo software does not match the robot specifications.
⇒
Load the correct AS and servo software.
_____________________________________________________________________
ERROR CODE D1012
Servo type mismatch. Check the settings.
Servo type set for the robot and servo software do not match.
⇒
Change the robot servo type setting
.
⇒
Install servo software that matches the robot setting.