beautypg.com

Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 130

background image

TROUBLESHOOTING

1-127

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE E4521

ABMA-PDP) Status OFFLINE. XX

An error occurred in the ABMA-PDP module, and the status of AnyBus PROFIBUS-DP
master changed to OFFLINE.

Use the sub-sub-code XX as a troubleshooting aid, clear the cause of the error and
reset the error.

If the error recurs, cycle the controller power OFF and ON.

_____________________________________________________________________

ERROR CODE E4522

ABMA-PDP) I/O data communication error. XX

During I/O communication, configuration data is downloaded to the interface card, then
communication is disconnected.

Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.

_____________________________________________________________________

ERROR CODE E4523

ABMA-PDP) sending of timed out I/O data. XX

The ABMA-PDP module is overloaded and output signals from the AS system cannot
be processed within the allowed time.

Check the fieldbus cable connections and repair as necessary.

Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.

_____________________________________________________________________

ERROR CODE E4524

ABMA-PDP) Timeout of receiving I/O data. XX

ABMA-PDP module overload, input signals from the slave cannot be processed within
the allowed time.

Check the fieldbus cable and connections, repair/replace as necessary

.

Use the sub-code XX as a troubleshooting aid, clear the cause of the error and reset
the error.