2 exxxx non-fatal error codes, Exxxx non-fatal error codes -59 – Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 62

TROUBLESHOOTING
1-59
August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Ka a a
w s k
1.3.2.2 EXXXX NON-FATAL ERROR CODES
ERROR CODE E0001
Unknown error.
Unregistered error occurred.
⇒
Contact KRI customer service (include operating conditions/settings and operation
log at the time the error occurred)
.
_____________________________________________________________________
ERROR CODE E0100
Abnormal comment statement exists.
Statements containing incorrect AS Language syntax can be included in a program as
comments. If the comment is not preceded with a semicolon (;) the step is executed as
a step and an error is generated.
⇒
Correct program comment syntax (add preceding semicolon).
⇒
Delete incorrect program step.
_____________________________________________________________________
ERROR CODE E0101
Nonexistent label.
Occurs when executing a GOTO command and the destination label is not defined.
Example: “IF x>0 GOTO 10” is specified, but the label “10” is not included in a program
step an error is generated.
⇒
Ensure valid labels are used within the program.
⇒
Delete the reference to the nonexistent label.
_____________________________________________________________________
ERROR CODE E0102
Variable is not defined.
Main causes include:
1. Variable data for a specific command/instruction is not defined.
Example: “x=SIN(y)” is specified and “y” is not defined.
2. Command/instruction contains incorrect AS Language syntax.
Example: “PCEND pcprog1” should be “PCEND 1”.
⇒
Ensure variables are properly defined.
⇒
Ensure correct AS Language command/instruction syntax is used.
_____________________________________________________________________