TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-68
August 9, 2005
Ka a a
w s k
ERROR CODE E1013
InterBus board is not installed.
The 1JF board is not installed.
⇒
Ensure the 1JF board is properly installed
.
⇒
Replace the 1JF board.
_____________________________________________________________________
ERROR CODE E1016
No. XX CC-LINK board is not installed.
The specified number 1HS board is not installed.
⇒
Installed the specified number 1HS board.
⇒
Ensure the specified number 1HS board is properly installed.
⇒
Replace the specified number 1HS board.
_____________________________________________________________________
ERROR CODE E1017
PLC error. Error code is Hex. XX.
This error occurs when a PC3JB (TOYOPUC) internal error is present (program memory
check sum error, parameter setting error, etc.).
⇒
Refer to the PC3JB (TOYOPUC) manual for the code (Hex. XX).
⇒
Replace the PC3JB (TOYOPUC).
_____________________________________________________________________
ERROR CODE E1018
INTER-BUS status error.
A processing error such as cable disconnection is detected at the 1JF board during
communication.
⇒
Refer to the 1JF board manual for information for checking error state displayed by
the front LED
.
⇒
Replace the 1JF board.
_____________________________________________________________________
ERROR CODE E1020
External equipment is abnormal.
An abnormality in peripheral equipment is detected by the PC3JB board
(TOYOPUC).
⇒
Check PC3JB board (TOYOPUC) peripheral equipment connections.
⇒
Ensure proper installation and connection of peripheral equipment.
_____________________________________________________________________