ERROR CODE E4014
TELNET) RECV error. CODE=XX.
During TCP/IP communication, data is not received due to a RECV (receive) error.
⇒
Check the communication line to the target end node and repair as necessary.
⇒
Check for problems at the target end node and repair as necessary.
⇒
The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4015
TELNET) IAC receive error. CODE=XX.
During TCP/IP communication, an error occurred when receiving data.
⇒
Check the communication line to the target end node and repair as necessary.
⇒
Check for problems at the target end node and repair as necessary.
⇒
Ensure the PC at the target end is using KCWIN TCP software.
⇒
The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4016
TELNET) Close failure. CODE =XX.
An error occurred in the LISTEN/ACCEPT function during an attempt to close the
socket. TCP/IP resources (queue or buffer) may be full. May be a problem with the
communication line or at the target end node.
⇒
Stop any other TCP/IP functions operating at the same time.
⇒
Cycle robot controller power OFF and ON.
⇒
The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________
ERROR CODE E4017
TELNET) Main socket close failure. CODE=XX.
An error occurred in the LISTEN/ACCEPT function during an attempt to close the main
socket. TCP/IP resources (queue or buffer) may be full. May be a problem with the
communication line or at the target end node.
⇒
Stop any other TCP/IP functions operating at the same time.
⇒
Cycle robot controller power OFF and ON.
⇒
The sub-error code (CODE=XX) is generated by the TCP/IP package. Refer to the
TCP/IP package manual.
_____________________________________________________________________