TROUBLESHOOTING
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
1-168
August 9, 2005
Ka a a
w s k
ERROR CODE P0144
Step:XX Preceding IF missing.
Displayed when control flow structure does not contain the correct structure for
IF…THEN… ELSE…END commands.
⇒
Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0145
Step:XX Preceding CASE missing.
Displayed when control flow structure does not contain the correct structure for
CASE…OF… VALUE…ANY…END commands.
⇒
Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0146
Step:XX Preceding DO missing.
Displayed when control flow structure does not contain the correct structure for
DO…UNTIL.
⇒
Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0147
Step:XX Cannot find END of XX.
Occurs when control flow structure that requires an END statement does not contain the
necessary END.
⇒
Use correct syntax and components in control flow structures.
_____________________________________________________________________
ERROR CODE P0148
Step:XX Too many control structures.
Occurs when 10 layers of control flow structure are exceeded.
⇒
Limit control flow structure to 10 layers.
_____________________________________________________________________