Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 64

TROUBLESHOOTING
1-61
August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Ka a a
w s k
ERROR CODE E0108
Divided by zero.
Occurs when the system encounters a mathematical evaluation that involves division by
“0”. Typically associated with the FRAME function and circular interpolation.
⇒
Check data source for calculations.
_____________________________________________________________________
ERROR CODE E0109
Floating point overflow.
Occurs when the system encounters a numeric floating point overflow in using arith-
metic (+, -, *, /) or logical (AND, OR, etc.) operators. This also occurs when converting a
numeric argument to an integer value.
⇒
Correct the program. Integer values with full precision ranges are from -16,777,216
to 16,777,216. For more information refer to the D Series Controller AS Language
Reference Manual.
_____________________________________________________________________
ERROR CODE E0110
String too long.
Character strings associated with arithmetic or comparative operators or the LEN func-
tion are too long (255 character maximum).
⇒
Correct the character string.
_____________________________________________________________________
ERROR CODE E0111
Attempted operation with neg. exponent.
Numeric values that have exponents must be positive in value.
⇒
Correct equations in program.
_____________________________________________________________________
ERROR CODE E0112
Too complicated expression.
Encountered numeric calculation too complex to be evaluated.
⇒
Simplify mathematical equations.
_____________________________________________________________________