Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 22

TROUBLESHOOTING
1-19
August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Ka a a
w s k
ERROR CODE D1002
Init. error of servo software.
Servo software
(armsc.mb)
initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
⇒
Reinstall servo software.
⇒
Check compatibility of AS and servo software and reinstall software as needed.
⇒
Replace the 1KA and or 1KB boards.
_____________________________________________________________________
ERROR CODE D1003
Init. error of servo control software.
Servo software
(armsv.abs)
initialization failure at controller power-up.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Incompatibility between the AS and servo software.
3. Defective 1KA and or 1KB board.
⇒
Reinstall servo software.
⇒
Check compatibility of AS and servo software and reinstall software as needed.
⇒
Replace the 1KA and or 1KB boards.
_____________________________________________________________________