Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 56

TROUBLESHOOTING
1-53
August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Ka a a
w s k
ERROR CODE D2020
[ARM CTRL BOARD] servo control software no response.
1KB board software stopped.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒
Reinstall correct 1KB board servo software to the 1KA board.
⇒
Replace 1KB board
.
_____________________________________________________________________
ERROR CODE D2021
Arm data file is not found.
When robot model is selected, data file corresponding to the installed arm is not found
in the system file.
⇒
Contact KRI customer service (include operating conditions/settings at the time the
error occurred)
.
_____________________________________________________________________
ERROR CODE D2022
Arm data is not found.
When robot model is selected, the arm data in the arm data file did not match the se-
lected robot.
⇒
Ensure the correct model setting is used
.
⇒
Ensure the correct software version is installed.
_____________________________________________________________________
ERROR CODE D2023
Failed to load arm data.
When robot model is selected, the arm data file for the selected robot model is incom-
patible with the AS software.
⇒
Ensure the correct model setting is used
.
⇒
Ensure the correct software version is installed.
_____________________________________________________________________