8

·

52

Error code stored to system memory

#170

#160

53

(H)

Cause

Measure

Replace the JW-20CM

Replace the JW-20CM

Check the communication

cable and slave module

Error
code
(HEX)

Check the communication cable

Check the switch setting

Replace the JW-20CM

FF

• After converting into octal, the lower two digits

represent the slave station number of the current
error. (Ex. C1

(H)

= 301

(8)

= slave station 01)

• Check the communication

cable

• Check for doubled allocation

of slave station number

• Replace the JW-20CM

Check the parameter setting
and switch

(3) Error code

When an error occurs in the JW-20CM, it stores the occurred error’s code to system memory #170

of each station’s PC.

01

ROM error, upper CPU

02

RAM error, upper CPU

03

2 port RAM error against PC, upper CPU

04

2 port RAM error against

communication CPU, upper CPU

11

ROM error, communication CPU

12

RAM error, communication CPU

18

Communication LSI error, communication CPU

1F

No response

20

More than one token detected

21

Doubled address detected

22

Fault of sending section

23

Token does not return within the rated interval

2A

Overflow of receiving buffer.

Occurs when the upper CPU processing is delayed.

2B

Flame length error

2C

Media error

30

EEPROM error

BE

BCC error

BF

Parameter setting error

C1

Communication error

In some cases, error code 23

(H)

or 2A

(H)

is stored when inputting power. This is not an error.

Check the communication cable

Replace the JW-20CM

to

1F

(H)

20

(H)

21

(H)

22

(H)

23

(H)

2A

(H)

2B

(H)

2C

(H)

30

(H)

BE

(H)

BF

(H)

C1

(H)

to

FF

(H)

This manual is related to the following products: