9

·

42

• Set “01

(H)

(=001

(8)

)” in parameter address 004002

(8)

and change to “relay/register link.”

(Operation example of JW-13PG)

Lower

Upper

00

(H)

·

In case of standard function, set top address by file address

(8)

.

In case of save memory function, set number of offset bytes.

004004

(8)

004005

(8)

004006

(8)

004007

(8)

Lower

Upper

00

(H)

·

00

(H)

: The top address is the same address of the master station

regardless of the value set at of 004004 to 004005

(8)

.

• Set the number of connecting stations (02 to 64

(D)

) including the master station in the parameter

address 004003

(8)

by octal.

• If you try to set values other than 02 to 64

(D)

, JW-20CM the displays 6F

(H)

error code.

From the previous page

Data link function setting [HEX (hexadecimal), byte]

Set number of connecting stations [DCM (decimal), byte]

Screen display of JW-13PG

Screen display of JW-13PG

Set top address of relay link area on slave station (01 to 77) (at standard function)/number of

offset bytes (memory capacity save function)

Slave

station

01

80

(H)

: The top address is different from the address of the master

station (Offset is valid).
For the save memory function, set in 80

(H)

.

004374

(8)

004375

(8)

004376

(8)

004377

(8)

00

(H)

Slave

station

77

(8)

80

(H)

To the next page

• In case of setting 0200 (file address 000200

(8)

) in parameter addresses 004004 to 004007

(8)

(slave station 01) and set 4 (number of off set bytes) in 004010

(8)

to 004013

(8)

(slave station 02).

(Example for page 11·10.)

• Set in parameter addresses 004004 to 004377

(8)

. These top addresses should not overlap the

register link area, flag area, or any area used by other option module.

04000 HEX 880
04001 HEX 00F
I PARAM.
>04002 HEX 01

04001 DCM 000
04002 DCM 001
I PARAM.
>04003 DCM 003

File address: OCT (octal), word

File number/flag: HEX (hexadecimal), byte

Set the "same" as or "different" from the

master station: HEX (hexadecimal) , bytes.

After converting into decimal

notation in 004003

(8)

, write “003.”

Write 001

(8)

to 004002

(8)