beautypg.com

Remarks – Sharp JW-20CM User Manual

Page 152

background image

9

·

54

80 40 20 10 8 4 2

Measure

Cause

Replace the JW-20CM

Check the communication cable

Check the communication

cable

Check the communication cable

Replace the JW-20CM

Check the parameter contents

Replace the JW-20CM

1

01

(H)

02

(H)

03

(H)

04

(H)

11

(H)

12

(H)

18

(H)

1F

(H)

20

(H)

21

(H)

22

(H)

23

(H)

2A

(H)

2B

(H)

2C

(H)

30

(H)

BE

(H)

BF

(H)

Error

code

(HEX)

C1

(H)

FF

(H)

Check the parameter
setting, switch

Check the communication

cable and slave module

LED name

• Check the communica-

tion cable

• Check for doubled allocation

of slave station number

• Replace the JW-20CM

• Occurs because of a media execution

error or noise from outside.

ON,

OFF

to

to

• Error codes “23” and “2A

(H)

” may occur when applying power. This is not an error.

• To check the communication cable, remove both connectors and short the connector terminals

at one end. Then measure the conductivity using a tester.

• Check the parameter and switch settings for all stations. If the settings are correct, replace

the JW-20CM or JW-20RS.

(Error code)

You need to select the "output error code for a slave station connection condition" at the master

station parameter addresses 007750 to 007757

(8)

. If more than one slave station has an error,

the slave station with the lowest station number will be displayed.

Remarks

ROM error, upper CPU

RAM error, upper CPU

2 port RAM error against PC, upper CPU

2 port RAM error against communication CPU, upper CPU

ROM error, communication CPU

RAM error, communication CPU

Communication LSI error, communication CPU

No response, communication CPU

More than one token detected

Doubled address detected

Fault of sending section

Token does not return within the rated interval

Over flow of receiving buffer.

Occurs when the upper CPU processing is delayed.

Flame length error

Media error

EEPROM error

BCC error

Parameter setting error

Communication error

• After converting into octal, the lower two digits

represent the slave station number of the current
error. (Ex. C1

(H)

= 301

(8)

= slave station 01)

This manual is related to the following products: