3 parameter memory table, Setting is necessary (1/6), Are 00 – Sharp JW-20CM User Manual
Page 204
13
·
3
Setting method (value, example)
(Operations when a slave station error occurs)
• Remote I/O operation (communication) stops
• The PC continues operation. (Mode 1)
• Only normal slave stations will continue
operation (communication).
• The PC continues operation. (Mode 2)
• Remote I/O operation (communication) stops
• The PC continues operation. (Mode 0)
• Remote I/O operation (communication) stops
• The PC continues operation. (Mode 1)
• Only normal slave stations will continue
operation (communication).
• The PC continues operation. (Mode 2)
• Remote I/O operation (communication) stops
• The PC continues operation. (Mode 1)
• Only normal slave stations will continue
operation (communication).
• The PC continues operation. (Mode 2)
• Remote I/O operation (communication) stops
• The PC also stops operation. (Mode 0)
• Remote I/O operation (communication) stops
• The PC continues operation. (Mode 1)
• Only normal slave stations will continue
operation (communication).
• The PC continues operation. (Mode 2)
001
(8)
002
(8)
004
(8)
005
(8)
006
(8)
011
(8)
012
(8)
014
(8)
015
(8)
016
(8)
(Communication
method)
Asynchronous
Synchronism
Asynchronous
Synchronism
000001
000000
: Setting is necessary (1/6)
Address
(8)
Set contents
Fix Manual
JW-PC
ZW-PC
Remote I/O
operation mode
No. of slave
station
connected
(1 to 63 sets)
(Decimal, bytes)
In case of 30 sets
030
(D)
13-3 Parameter memory table
(1) JW-20CM
Remote I/O
• Initial value of the address 000000, 000001
(8)
are 00
(H)
.
Fix Manual