Sharp JW-20CM User Manual
Page 59
8
·
21
[I/O table registration in case of using JW-I/O]
1. In case of not setting dummy I/O
Register I/O table based on the installed I/O module. (Set parameter address 001001
(8)
= 65
(H)
, the
procedure B in the flow chart.)
However, in case of parameter address of JW-20RS 001002
(8)
= 00
(H)
(default setting), the JW-20CM
automatically registers I/O table when the power is input and there is no need to register I/O table.
(Procedure A in the flow chart.)
2. In case of setting dummy I/O
Set number of dummy I/O points for each slot and registers I/O table based on this setting and the
installed I/O module. (Set parameter address 001001
(8)
= 64
(H)
, procedure C in the flow chart.)
Procedure D in the flow chart is special method to set byte of I/O module for each slot. Normally set
I/O module type using steps 1 and 2 above.
No
Yes
No
Yes
to
are applied to page 8·24 to 29.
8·29
8·28
8·27
8·26
8·25
Not setting dummy I/O
Auto setting the kinds of I/O module
(Auto I/O
registration)
Manual I/O registration)
Set no. of dummy I/O points
Not setting the kinds of I/O module
(auto setting)
Set the kinds of I/O module
Registration of I/O table
(parameter address 001001
(8)
= 65
(H)
)
Registration of I/O table
(parameter address 001001
(8)
= 64
(H)
)
Registration of I/O table
(parameter address 001001
(8)
= 64
(H)
)
Set max. racks, slot number
Set remote I/O top address
D
C
B