Set top address of relay link area.
· Set file address in parameter address 007730 to 007733
(8)
.
These top addresses should not overlap the register link area, flag area, or any area used by
other option module.
In case of setting 1000 (file address 001000
(8)
) using JW-13PG : Example for slave station 02 of
page 9·41.
“When PC is JW model and the memory capacity save function is used”
Set register link area of register link area.
· Set file address in parameter address 007734 to 007737
(8)
.
These top addresses should not overlap the relay link area, flag area, or any area used by other
option module.
In case of setting 09000 (file address 004000
(8)
) using JW-13PG : Example for slave station 02 of
page 9·41.
To the next page
Screen display of JW-13PG
Screen display of JW-13PG
Lower
Upper
00
(H)
007730
(8)
007731
(8)
007732
(8)
007733
(8)
File address
7
7
MNTR
1
Write 001000
(8)
Write parameter address 007732 to 007733
(8)
for 000000
(8)
.
Display the contents of parameter address
007730 to 007731
(8)
.
07726 0 000000
07730 0 001000
I PARAM.
>07732 0 000000
Lower
Upper
File number
File address
007734
(8)
007735
(8)
007736
(8)
007737
(8)
4
Write parameter address 007734 to
007735
(8)
for 004000
(8)
.
Write parameter address 007736
(8)
for file number 0.
07716 D 00000
07720 D 00004
I PARAM.
>07722 D 00008