Remarks – Sharp JW-20CM User Manual
Page 67
8
·
29
"Only when using JW model I/O module"
Setting remote I/O top address
[OCT (octal), word]
(Applied to item
on pages 8·20 to 22)
· In order to light a search module (SU) lamp, set remote I/O top address of each slave station
which are allocated in the master station using file address into parameter address 001004 and
001005
(8)
.
001000(8)
Lower bits
001000(8)
Upper bits
(When to set file address 000200( 0200) using the JW-13PG)
Display on the JW-13PG
01000 0 000006
01002 0 000003
I PARAM.
>01004 0 000200
Display contents of address
00104
(8)
Word
display
(Octal)
(
)
Write file address
000200
(8)
· Though input output relays, auxiliary
relays etc. of the PC are allocated their
byte addresses for each item, allocate
the file address which are allocated
throughout the memory register range.
File address
000000
000377
000400
000677
000700
000777
001000
001577
Byte address
0000
0377
0400
0677
0700
0777
1000
Input/output relays
Auxiliary relay
Latch relay
General purpose relay
[Operation method of I/O search (slave station): In case of JW-13PG]
Connect the JW-13PG to the slave module JW-20RS in which an I/O shall be searched.
· Assign byte address
· Assign rack number and slot number
SHIFT
1
RESET
Select I/O
search mode
Select byte
address
assignment
Set byte address in
octal
(Light)
(Light OFF)
Continous search
SHIFT
1
1
RESET
(Light)
(Light OFF)
Continous search
Select I/O
search mode
Select rack
and slot No.
assignment
Set rack number
in octal
Set slot number in
hexadecimal
Remarks