beautypg.com

Sharp JW-20CM User Manual

Page 194

background image

11

·

7

Operation example

This paragraph describes an operation example using the multipurpose programmer: JW-50PG.

For operations with other support tools, see the attached instruction manuals.

• Connect the JW-50PG to the JW-20CM on

the satellite net.

• Set communication mode

Set the communication mode of the JW-50PG to “Network CONCT.” and this enables remote

programming and remote monitor.

Select “Initial setting.”

Select “COM. set.”

Select “Network CONCT.”

• Network setting

Select whether the target station for remote

programming or remote monitor is on the

standard network connection or on the

extension network connection.

In the case below, 10 to 12

(8)

are standard

network connections. 01 to 03

(8)

are extension

network connections.

(JW-50PG)

Satellite net

10

(8)

11

(8)

12

(8)

00

(8)

01

(8)

02

(8)

03

(8)

(JW-50PG)

This manual is related to the following products: