Are all 00 – Sharp JW-20CM User Manual
Page 205
13
·
4
(2/6)
Setting method
(value, example)
Fix
• Use the addresses 000006 to 000177
(8)
listed below when the manual allocation mode is selected. These
addresses cannot be used in the fixed allocation mode.
• Initial value of the address 000002 to 000177
(8)
are all 00
(H)
.
Address
(8)
000006, 000007
000010, 000011
000012, 000013
000014, 000015
000016, 000017
000020, 000021
000022, 000023
000024, 000025
000026, 000027
000030, 000031
000032, 000033
000034, 000035
000036, 000037
000040, 000041
000042, 000043
000044, 000045
000046, 000047
000050, 000051
000052, 000053
000054, 000055
000056, 000057
000060, 000061
000062, 000063
000064, 000065
000066, 000067
000070, 000071
000072, 000073
000074, 000075
000076, 000077
Set contents
Remote I/O top address of slave station 03
(same as 000004, 000005)
04 (same as 000004, 000005)
05 (same as 000004, 000005)
06 (same as 000004, 000005)
07 (same as 000004, 000005)
10 (same as 000004, 000005)
11 (same as 000004, 000005)
12 (same as 000004, 000005)
13 (same as 000004, 000005)
14 (same as 000004, 000005)
15 (same as 000004, 000005)
16 (same as 000004, 000005)
17 (same as 000004, 000005)
20 (same as 000004, 000005)
21 (same as 000004, 000005)
22 (same as 000004, 000005)
23 (same as 000004, 000005)
24 (same as 000004, 000005)
25 (same as 000004, 000005)
26 (same as 000004, 000005)
27 (same as 000004, 000005)
30 (same as 000004, 000005)
31 (same as 000004, 000005)
32 (same as 000004, 000005)
33 (same as 000004, 000005)
34 (same as 000004, 000005)
35 (same as 000004, 000005)
36 (same as 000004, 000005)
37
(same as 000004, 000005)
000100, 000101
000102, 000103
000104, 000105
000106, 000107
000110, 000111
000112, 000113
000114, 000115
000116, 000117
000120, 000121
000122, 000123
000124, 000125
000126, 000127
000130, 000131
000132, 000133
000134, 000135
000136, 000137
000140, 000141
000142, 000143
000144, 000145
000146, 000147
000150, 000151
000152, 000153
000154, 000155
000156, 000157
000160, 000161
000162, 000163
000164, 000165
000166, 000167
000170, 000171
000172, 000173
000174, 000175
000176, 000177
000002
000003
000004
000005
Address
(8)
Set contents
(Octal, word)
When 0200,
set to 000200
(8)
• When using the fixed allocation mode, put the
top address of the remote I/O in this register.
• When using the manual allocation mode, put
the top address of the remote I/O in the slave
station 01 in this register.
Set remote I/O top address of slave station 02
(Octal, word)
When 0300,
set to 000300
(8)
Manual
JW-PC
ZW-PC
Fix Manual
Remote I/O top address of slave station 40
(same as 000004, 000005)
Address
(8)
Set contents
41 (same as 000004, 000005)
42 (same as 000004, 000005)
43 (same as 000004, 000005)
44 (same as 000004, 000005)
45 (same as 000004, 000005)
46 (same as 000004, 000005)
47 (same as 000004, 000005)
50 (same as 000004, 000005)
51 (same as 000004, 000005)
52 (same as 000004, 000005)
53 (same as 000004, 000005)
54 (same as 000004, 000005)
55 (same as 000004, 000005)
56 (same as 000004, 000005)
57 (same as 000004, 000005)
60 (same as 000004, 000005)
61 (same as 000004, 000005)
62 (same as 000004, 000005)
63 (same as 000004, 000005)
64 (same as 000004, 000005)
65 (same as 000004, 000005)
66 (same as 000004, 000005)
67
(same as 000004, 000005)
70 (same as 000004, 000005)
71 (same as 000004, 000005)
72 (same as 000004, 000005)
73 (same as 000004, 000005)
74 (same as 000004, 000005)
75 (same as 000004, 000005)
76 (same as 000004, 000005)