beautypg.com

SANRAD I3.1.1205 User Manual

Page 96

background image

6-4

SANRAD V-Switch CLI User Manual


You need to define two parameters to blink a storage device:

S

WITCH

P

ARAMETER

D

EFINITION

S

TATUS

E

XAMPLE

-s

STORAGE DEVICE

ALAIS OF DEVICE
TO BLINK

MANDATORY

Stor_1

-t

TIME

LENGTH OF TIME TO
BLINK DEVICE

OPTIONAL

1-3600

SEC

0=

FOREVER

DEFAULT

:

0

120

Example:

The storage device, Stor_1, is set to blink for two minutes (one hundred and
twenty seconds) to allow it to be identified.

storage blink activate –s Stor_1 –t 120

Use the CLI command storage blink abort to stop the blinking before the
end of the set time.

storage blink abort

You need to define one parameter to stop blinking a storage device:

S

WITCH

P

ARAMETER

D

EFINITION

S

TATUS

E

XAMPLE

-s

STORAGE DEVICE

ALAIS OF DEVICE
TO BLINK

MANDATORY

Stor_1

Once a storage device has been identified, use the CLI command storage set
to change the device alias or include helpful information on the device.

storage set

S

WITCH

P

ARAMETER

D

EFINITION

S

TATUS

E

XAMPLE

-s

STORAGE ALIAS

STORAGE ALIAS TO
MODIFY

MANDATORY

Stor_1

-na

NEW ALIAS

NEW ALIAS FOR
STORAGE

OPTIONAL

Disk2JBOD5

-info

INFORMATION

INFORMATION ON
STORAGE TO SET

OPTIONAL

save_for_snap
shots

Example: