Chapter 10: Routine V-Switch Maintenance
10-23
system copy
You need to define two parameters to copy a file between the flash and compact
flash:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-from
FROM
WHERE TO COPY
FROM
MANDATORY
FLASH
CFLASH
cflash
-type
TYPE
TYPE OF FILE TO
COPY
MANDATORY
DB
:
DATABASE
db
system copy –from cflash –type db
If you want to load
Safe Mode
The V-Switch operating status includes the ability to enter into safe mode in the
event of booting problems or in an attempt to clear significant amounts of a V-
Switch configuration. There are two ways to enter safe mode:
Automatically during a reboot.
Manually via CLI.
There are four safe mode reboot options:
Level 0: Reboot in normal mode.
Level 1: Reboot with last good configuration.
Level 2: Reboot with default factory database.
Level 3: Reboot with default factory system.