Viewing the fc port information, Configuring an fc storage port – SANRAD I3.1.1205 User Manual
Page 65

Chapter 4: V-Switch Configuration
4-13
Example
Storage port 3, pscsi3, is assigned SCSI bus ID 12.
pscsi set busid –if pscsi3 –id 12
Viewing the FC Port Information
Use the CLI command fc interface show to view all FC ports on the V-
Switch; their World Wide Port Names (WWPN) and administrative and
operative types.
fc interface show
Alias
WWPN
Connect
Mode
Oper
Type
Speed
fc1
20:00:00:20:38:11:34:78
Private
NlPort
1Gbs
fc2
20:00:00:20:38:00:10:64
Private
NlPort
1Gbs
Configuring an FC Storage Port
The V-Switch default configuration for FC connections is 1 GB nl port in a
public loop. If you want to change the default configuration, each storage port
connected to an FC device can be reconfigured to change the connection speed,
port type and connection mode. Use the CLI command fc set to change the
FC storage port communication speed; the port type or connection mode.
fc set
You need to define four parameters to reconfigure an FC port:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-if
INTERFACE
STORAGE PORT
MANDATORY
fc2
-sp
SPEED
FC
COMMUNICATION
SPEED
OPTIONAL
AUTO
:
0
1
GB:
1
2
GB:
2
1
-pt
PORT TYPE
TYPE OF
FC
PORT
OPTIONAL
N OR NL
nl
-cm
CONNECTION MODE
OPTIONAL
FAB
:
FABRIC
PRL
:
PRIVATE
LOOP
PUL
:
PUBLIC
LOOP
private