5-4

SANRAD V-Switch CLI User Manual

RAID controller are simultaneously exposed through all ports connected
to both V-Switches for the V-Switches to provide high availability during a
V-Switch failover.

In Figure 5-2, V-Switch 1 has gone off-line. V-Switch 2 activates V-Switch 1’s IP
address and takes over exposure of Volume 1 to Host 1, represented by the
orange dashed line.

Host 1 continues to access Volume 1 through the same IP address as it did
before its V-Switch went off-line. Host 1 has no way of knowing that its regular
V-Switch is off-line. Host 1’s storage performance is not impacted by the off-
line V-Switch.