Upgrading the v-switch software – SANRAD I3.1.1205 User Manual
Page 207
Chapter 10: Routine V-Switch Maintenance
10-21
Upgrading the V-Switch Software
The V-Switch must
be reset for the new
software to begin
functioning.
You can upgrade the V-Switch software via CLI. The software upgrade
files are first downloaded from the TFTP server. You can then use the CLI
command ft update to upgrade the V-Switch software. There are a
total of six upgrade files. Do not change their names or the V-Switch will
not be able to perform the upgrade.
All configured user profiles are unaffected by the software upgrade.
ft update
You need two parameters to upgrade the V-Switch software:
S
WITCH
P
ARAMETER
D
EFINITION
S
TATUS
E
XAMPLE
-ip
IP
ADDRESS
TFTP
SERVER
IP
ADDRESS
MANDATORY
212.199.43.46
-fd
DIRECTORY
DIRECTORY TO
TAKE FILES FROM
OPTIONAL
sanrad/update
/v2_0/
Example:
ft update –ip 212.199.43.46 –fd sanrad/update/v2_0/
After upgrading the software, the V-Switch must be reset for the new software
to begin functioning. Use the CLI command reset to reset the V-Switch.
reset
Use the CLI command info to view the software version to confirm that the
software has successfully upgraded.