Health monitoring, System hardware show – SANRAD I3.1.1205 User Manual
Page 288
12-2
SANRAD V-Switch CLI User Manual
Health Monitoring
You can monitor the health of the V-Switch hardware for fan malfunctions that
could lead to overheating as well as power supply malfunctions both of which
can nullify high availability and lead to V-Switch failover.
system hardware show
This command shows all hardware interface connection statistics.
system hardware show
Table 12-1: System
Hardware
Max No. of Power Supplies:
2
PS Status:
1 working
Max No. of Fans:
3
Fan Status:
3 working
CPU Temperature (C):
59
CPU Temperature Threshold (C):
Warning 90;
Faulty 100
CPU Temperature Status:
OK
On-board Temperature (C):
33
On-board Temperature Threshold (C):
Warning 60;
Faulty 70
On-board Temperature Status
OK
You can change the default temperature scale to Fahrenheit using the CLI
command device set –temperature_units f.