SANRAD I3.1.1205 User Manual
Page 326

A-26
SANRAD V-Switch User Manual
STEP 2.
P
OWER UP STORAGE DEVICE
Power up the JBOD appliance first to allow both V-Switches to register it in
their network scan.
STEP 3.
POWER UP
V-S
WITCHES
Connect the power cord to V-Switch 1 and then to the electric socket. The
V-Switch powers up. The fan assembly is running and the LCD panel
displays:
V-Switch 3000
Status: OK
Connect the power cord to V-Switch 2 and then to the electric socket. The
V-Switch powers up. The fan assembly is running and the LCD panel
displays:
V-Switch 3000
Status: OK
STEP 4.
I
NITIALIZE
V-S
WITCH
1
Use the LCD display and control buttons on V-Switch 1 to configure the V-
Switch management port IP address and mask.
Toggle to the IP Configure ETH1 Port screen.
Press Enter. The IP Configuration screen appears.
IP CONFIG
Press Enter again. The IP Config ETH1 Port screen appears.
IP Config
ETH1 Port
Press Enter. The Insert IP screen appears.
Insert IP
0 0 0.0 0 0.0 0 0.0 0 0
Enter the management port IP address. The left/right buttons toggle
between places in the IP address. The up/down buttons scroll between
numbers. Press Enter after inputting the full address.
Insert IP
2 1 2.1 9 9.0 4 3.0 4 1
Press Enter to enter the IP address and progress to the IP Mask screen.
Mask
2 5 5.2 5 5.2 5 5.0 0 0
If you want to change from the default mask, use the left/right buttons to
toggle between places in the mask and the up/down buttons scroll between
numbers.