336

SMSC LAN9311/LAN9311i

DATASHEET

14.5.2.13

Port x MAC Receive Multicast Count Register (MAC_RX_MULCST_CNT_x)

This register provides a counter of valid received packets with a multicast destination address. The
counter is cleared upon being read.

Note:

A bad packet is one that has a FCS or Symbol error.

Register #:

Port0: 041Ah

Size:

32 bits

Port1: 081Ah
Port2: 0C1Ah

BITS

DESCRIPTION

TYPE

DEFAULT

31:0

RX Multicast
Count of good packets (proper length and free of errors), including MAC
control frames, that have a multicast destination address (not including
broadcasts).

Note:

This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.

RC

00000000h