beautypg.com

Section 14.5.2.12, Datasheet – SMSC LAN9311i User Manual

Page 335

background image

Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface

Datasheet

SMSC LAN9311/LAN9311i

335

Revision 1.4 (08-19-08)

DATASHEET

14.5.2.12

Port x MAC Receive CRC Error Count Register (MAC_RX_CRCERR_CNT_x)

This register provides a counter of received packets that with CRC errors. The counter is cleared upon
being read.

Register #:

Port0: 0419h

Size:

32 bits

Port1: 0819h
Port2: 0C19h

BITS

DESCRIPTION

TYPE

DEFAULT

31:0

RX CRC
Count of packets that have between 64 and the maximum allowable number
of bytes and have a bad FCS, but do not have an extra nibble. The max
number of bytes is 1518 for untagged packets and 1522 for tagged packets.
If Jumbo2K (bit 3) is set in the

Port x MAC Receive Configuration Register

(MAC_RX_CFG_x)

, the max number of bytes is 2048.

Note:

This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 137 hours.

RC

00000000h

This manual is related to the following products: