Power requirements, Environmental specifications, Powering on – Fortinet FortiGate-800 User Manual
Page 27
Getting started
Powering on
FortiGate-800 Installation and Configuration Guide
27
Power requirements
• Power dissipation: 300 W (max)
• AC input voltage: 100 to 240 VAC
• AC input current: 6 A
• Frequency: 50 to 60 Hz
Environmental specifications
• Operating temperature: 41 to 95°F (5 to 35°C)
• Storage temperature: -4 to 176°F (-20 to 80°C)
• Humidity: 10 to 90% non-condensing
Powering on
To power on the FortiGate-800 unit
1
Make sure that the power switch on the back is turned off.
2
Connect the power cable to the power connection on the back of the FortiGate unit.
3
Connect the power cable to a power outlet.
4
Turn on the power switch.
After a few seconds, SYSTEM STARTING appears
on the LCD.
MAIN MENU appears on the LCD when the system
is running.
Table 1: FortiGate-500 LED indicators
LED
State
Description
Power
Green
The FortiGate unit is powered on.
Off
The FortiGate unit is powered off.
Internal
External
DMZ
HA
1 to 4
Amber
The correct cable is in use and the connected equipment has
power.
Flashing
amber
Network activity at this interface.
Green
The interface is connected. Internal, External, DMZ and HA
connect at up to 1000 Mbps. Interfaces 1, 2, 3 and 4 connect at
up to 100 Mbps.
Off
No link established.