beautypg.com

General troubleshooting – Baseline Systems BaseStation 6000 User Manual

Page 117

background image

P a g e

| 109

General Troubleshooting

Problem

Symptoms /Cause

Possible Fixes

System activates

valve and shows that

it is watering but no

water comes on.

Water may be turned off or

the valve is faulty or clogged.

• Make sure water is turned on to Master

valve.

• If the solenoid for the problem zone is

buzzing or clicking, check valve

diaphragm and solenoid.

Errors are reported

on zones and

watering is

intermittent.

Bad or marginal wiring or

connections is usually the

cause of this problem.

• Check wiring using the Baseline Wire

Tester (Model #BI-WIT).

• Check connections. If in doubt, cut out

the connection and reconnect.

• Test the common ground wire to the

earth ground. Resistance should be

greater than 1M ohms.

• Check the common wire. Apply voltage to

a valve (turn on valve). Attach a

voltmeter negative (-) lead to the

common and the positive (+) lead to the

power or hot wire. If there is no voltage,

take the voltmeter negative (-) lead and

put in ground. If there is voltage, then the

common is bad.

Valve is turned on

when it should not

be.

Valve has been turned

manually in the field.

Valve is accidentally wired to

the two-wire path.

• Check valve and wiring in the field.