beautypg.com

HP LC 2000 User Manual

Page 23

background image

Chapter 2

Controls, Ports and Indicators

15

Power Supply Module Indicator

Each HP NetServer power supply module has an indicator as shown in Figure 2-5,
and each power supply has its own power cord connection. The HP NetServer
comes with one power supply module standard, and a second power supply
module for redundancy is optional.

Power
Indicator

Release
Latch

Handle

Strainrelief

Figure 2-5. Power Supply LED

NOTE

The release latch, which is spring loaded, must be up to insert
the power cord. The power supply can not be removed from the
chassis with the power cord connected to the AC In connector.
The power cord must be removed before pushing down on the
release latch to free the power supply from the chassis.

Table 2-5. Power Supply LED Indicator Descriptions

Green LED

Power Supply and NetServer Status

Steady Green

This indicates the HP NetServer is powered up and operating
normally, or is in an ACPI suspend state.

Off

This indicates the NetServer is powered off, the AC line cord
is unplugged, or the power supply has failed, which may
include a fan failure (turning too slowly). If a fan fails in one
of two supplies, the defective supply will continue to operate
until it reaches the thermal shutdown limit. The second power
supply (redundant power supply) will continue to operate
providing the necessary power. Refer to Chapter 12,
"Troubleshooting."