4meter proving – ProSoft Technology MVI56-AFC User Manual
Page 41
MVI56-AFC ♦ ControlLogix Platform
Meter Proving
Liquid and Gas Flow Computer
User Manual
ProSoft Technology, Inc.
Page 41 of 316
February 25, 2011
4
Meter Proving
In This Chapter
Prover Configuration ............................................................................. 42
Setting up the AFC module for Meter Proving ....................................... 51
Meter Proving Reports........................................................................... 63
Protected Meter Proving Data in the AFC's Input Register Bank .......... 64
As meters continue to be used over time, the meter’s measurement accuracy
deteriorates. Many things can cause the flow sensor bearings to wear down
beyond specified limits so that meters are measuring lower volume levels
causing producers to pump more oil than the consumer is buying. Meter Provers
have a “Known Traceable Volume” which allows using actual flowing and
operating conditions to establish a meter correction factor to restore
measurement accuracy.
There are 4 types of provers. This chapter will give a basic overview for each
type, its options, and configuration.
The Unidirectional Pipe Prover
The Bidirectional Pipe Prover
The Compact Prover
The Master Meter