beautypg.com

1introduction – ProSoft Technology MVI56-AFC User Manual

Page 11

background image

MVI56-AFC ♦ ControlLogix Platform

Introduction

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 11 of 316

February 25, 2011

1

Introduction

In This Chapter

Update Notice ........................................................................................ 12

MVI56-AFC Module ............................................................................... 14

Configuration Modification Lockout and Seal ........................................ 15



The MVI56-AFC Flow Computer module performs measurement of hydrocarbon

gases and liquids using currently accepted industry measurement standards. The

module consists of a single-slot solution for Rockwell Automation chassis. To

obtain its process inputs for calculations, the module uses the process data

collected by analog and pulse I/O modules. The processor transfers this data to

the AFC module, which then calculates flow rates, accumulated volumes, and

accumulated mass. The results of the calculations are transferred back to the

processor for use in the application logic, or for transfer to a SCADA host.
The module has two communication ports for Modbus communication allowing

easy access to a remote Modbus device. The module works as a Modbus slave

or master device.
As discussed later in this manual, the internal Modbus database can be

accessed by a Modbus Master device and by the processor (using the Modbus

Gateway Function).
The AFC Manager software can be used for easy meter configuration and

application monitoring. Refer to the AFC Manager User Manual for complete

information about this tool.
The following section provides a sample application where input data is

transferred from the transmitters to analog input cards on the Rockwell

Automation rack and the values are transferred from the processor to the module

(the module supports floating-point, scaled integer, or 4 to 20 mA format).
For Pulse meter applications, the pulse count and pulse frequency values are

typically transmitted through high-speed counter modules in the rack.
The module performs the flow calculation based on the values transferred

through the backplane. The calculation results can be read to the processor or

polled from a remote Modbus master unit connected to one of the communication

ports.

This manual is related to the following products: