11.2.4 Function Block Definition - 4, 5, 6 & 7: Modbus Pass Through

Output Function Block ID

Input Function Block ID

Function Block Name:

Modbus pass-through

Function Block ID:

6 decimal, 000110 binary, 6144 dec.

Target:

Global

Data Block Length:

User Defined - from 3 to 127

Total Block Length:

(User Defined + 1) Elements