Markings

Electrical Ratings

Backplane Current Load: 800 mA @ 5.1 Vdc; 3 mA @ 24 Vdc

Operating Temperature: 0°C to 60°C (32°F to 140°F)

Storage Temperature: -40°C to 85°C (-40°F to 185°F)

Shock: 30 g, operational; 50 g, non-operational; Vibration: 5 g from 10 Hz to 150 Hz

Relative Humidity: 5% to 95% with no condensation

All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least

4mm(squared).

Label Markings

ATEX
II 3 G
EEx nA IIC T6
0°C <= Ta <= 60°C

cULus
E183151
Class I Div 2 Groups A,B,C,D
T6
-30°C <= Ta <= 60°C

Agency Approvals and Certifications

Agency

Applicable Standard

RoHS

CE

EMC-EN61326-1:2006; EN61000-6-4:2007

ATEX

EN60079-15:2003

cULus

UL508; UL1604; CSA 22.2 No. 142 & 213

CB Safety

CA/10533/CSA
IEC 61010-1 Ed.2; CB 243333-2056722 (2090408)

GOST-R

EN 61010

CSA

EN 61010

243333

ME06

E183151