MVI56-AFC Backplane Communication

MVI56-AFC ♦ ControlLogix Platform

User Manual

Liquid and Gas Flow Computer

Page 164 of 316

ProSoft Technology, Inc.

February 25, 2011

Output Function Blocks (OFB)
The architecture of the Output Block Array provides you with a flexible and

powerful way to interface the process and other data to the AFC module. A

number of pre-defined Output Function Blocks are at your disposal to implement

as required. Each Output Function Block type carries out a specific function. For

example, the Meter Process Variable Output Function Block transfers the

process variables (temperature, pressure, meter pulses, and so on) to a specific

target meter channel in the AFC module. The calculated flow rates, product

accumulators, and so on are returned to the controller by the AFC in the

associated Input Function Block (IFB) as part of the Input Block Array (IBA). In

the same way a Wall Clock Function Block allows you to synchronize the AFC

Wall Clock to the processor Wall Clock. Like Lego blocks of various sizes, these

function blocks can be stacked together in the data portion of the Output Block

Array as shown in the following diagram:

Element #

Attribute

0

Sentinel (Transaction Number)

1

Output Block Length (OBL<=245)

2

Global
Wall Clock

Function Block: 7

Elements

3

Meter 2
Process Variable

Function Block:

12 Elements

.

Space for User Allocated Function Blocks

Meter 3
Process Variable

Function Block:

12 Elements

.

(Total Available Elements = 245)

Meter 3
Analysis

Function Block:

25 Elements

57

.

.

244

245

246

247

Anchor (Transaction Number)