Pulse Frequency Integration with Gas Product

Meter PV: Output Function Block

Meter PV: Input Function Block

Element

Attribute

Element

Attribute

0

Block ID: Function Code & Meter

Number

0

Block ID: Function Code, Meter

Number, Active Stream Number

1

Reserved

1

Meter Alarms (Bitmap)

2

Temperature LS (see Note)

2

Net Accumulator LS (double

integer)

3

Temperature MS

3

Net Accumulator MS (double

integer)

4

Pressure LS (see Note)

4

Net Flow Rate LS (float)

5

Pressure MS

5

Net Flow Rate MS (float)

6

Reserved

6

Gross Flow Rate LS (float)

7

Reserved

7

Gross Flow Rate MS (float)

8

Reserved

8

Fpv LS (float)

9

Reserved

9

Fpv MS (float)

10

Meter Pulse Freq: Hz LS (float)

10

Cprime LS (float)

11

Meter Pulse Freq: Hz MS (float)

11

Cprime MS (float)

Flow Rate Integration with Liquid Product

Meter PV: Output Function Block

Meter PV: Input Function Block

Element

Attribute

Element

Attribute

0

Block ID: Function Code & Meter

Number

0

Block ID: Function Code, Meter

Number, Active Stream Number

1

Water % (see Note)

1

Meter Alarms (Bitmap)

2

Temperature LS (see Note)

2

Net Accumulator LS (double

integer)

3

Temperature MS

3

Net Accumulator MS (double

integer)

4

Pressure LS (see Note)

4

Net Flow Rate LS (float)

5

Pressure MS

5

Net Flow Rate MS (float)

6

Flow Rate LS (see Note)

6

Gross Accumulator LS (double

integer)

7

Flow Rate MS

7

Gross Accumulator MS (double

integer)

8

Density LS (see Note)

8

Gross Standard Accumulator LS

(double integer)

9

Density MS

9

Gross Standard Accumulator MS

(double integer)

10

Reserved

10

Mass Accumulator LS (double

integer)

11

Reserved

11

Mass Accumulator MS (double

integer)

This manual is related to the following products: