beautypg.com

ProSoft Technology MVI56-AFC User Manual

Page 177

background image

MVI56-AFC ♦ ControlLogix Platform

MVI56-AFC Backplane Communication

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 177 of 316

February 25, 2011

Orifice Meter with Gas Product

Meter PV: Output Function Block

Meter PV: Input Function Block

Element

Attribute

Element

Attribute

0

Block ID: Function Code &

Meter Number

0

Block ID: Function Code, Meter

Number, Active Stream Number

1

Reserved

1

Meter Alarms (Bitmap)

2

Temperature LS (see Note)

2

Net Accumulator LS (double

integer)

3

Temperature MS

3

Net Accumulator MS (double

integer)

4

Pressure LS (see Note)

4

Net Flow Rate LS (float)

5

Pressure MS

5

Net Flow Rate MS (float)

6

Differential Pressure LS (see

Note)

6

Gross Flow Rate LS (float)

7

Differential Pressure MS

7

Gross Flow Rate MS (float)

8

Reserved

8

Fpv LS (float)

9

Reserved

9

Fpv MS (float)

10

Reserved

10

Cprime LS (float)

11

Reserved

11

Cprime MS (float)

Pulse Meter with Gas Product

Meter PV: Output Function Block

Meter PV: Input Function Block

Element

Attribute

Element

Attribute

0

Block ID: Function Code &

Meter Number

0

Block ID: Function Code, Meter

Number, Active Stream Number

1

Reserved

1

Meter Alarms (Bitmap)

2

Temperature LS (see Note)

2

Net Accumulator LS (double

integer)

3

Temperature MS

3

Net Accumulator MS (double

integer)

4

Pressure LS (see Note)

4

Net Flow Rate LS (float)

5

Pressure MS

5

Net Flow Rate MS (float)

6

Meter Pulses LS (double

integer)

6

Gross Flow Rate LS (float)

7

Meter Pulses MS (double

integer)

7

Gross Flow Rate MS (float)

8

Reserved

8

Fpv LS (float)

9

Reserved

9

Fpv MS (float)

10

Meter Pulse Freq: Hz LS (float)

10

Cprime LS (float)

11

Meter Pulse Freq: Hz MS (float)

11

Cprime MS (float)