3.4

Gas Product Overview

The gas compressibility calculations are based on molar analysis concentrations

of up to 21 components, using the Detail Characterization Method of AGA8

(1992). The module automatically generates alarms if the sum of the molar

concentrations is not 100%
Configure the analysis settings using the AFC Manager (Meter Configuration /
Analysis Config
) as follows. This window allows the selection of the

components(Component Selection Map) and analysis precision (Precision and

Stream Assignment – version 2.06.000 or higher). The sample ladder logic

assumes that all components are selected so check all components at the

Component Selection Map window.

Enter the gas analysis concentrations by clicking the Analysis button.You can

also update the concentrations through the backplane as will be later shown in

this User Manual.

The module records events every time a molar concentration value changes. For

applications that involve gas chromatograph devices, this feature might not be

desirable because it is expected that the values should frequently change. You

can disable this feature using AFC Manager (Meter Configuration / Control
Options
/ Treat Analysis as Process Input).