MVI56-AFC ♦ ControlLogix Platform

Archives

Liquid and Gas Flow Computer

User Manual

ProSoft Technology, Inc.

Page 101 of 316

February 25, 2011

The module reserves 1060 words for daily archives and 1440 words for hourly

archives. Because the default configuration sets the record size for 30 words, it

means that the maximum (default) number of archives per meter channel is 35

daily archives and 48 hourly archives. However, because you can change the

number of words per archive, the actual maximum number of archives per meter

channel will depend on the configured number of words per archive as follows:

Number of Words per
Archive

Number of Daily Archives

Number of Hourly Archives

10

106 daily archives

144 hourly archives

20

53 daily archives

72 hourly archives

30

35 daily archives

48 hourly archives

40

26 daily archives

36 hourly archives


You may also configure the accumulator type for each archive. You must

configure one of the following options:
Mass
Energy (Gas product only)
Net Volume
Gross Volume
Gross Standard
Water Volume (Liquid product only)
The following topics show the default archive structure when you configure a new

meter. You can edit this structure according to your own requirements.