ProSoft Technology MVI56-AFC User Manual
Page 101
MVI56-AFC ♦ ControlLogix Platform
Archives
Liquid and Gas Flow Computer
User Manual
ProSoft Technology, Inc.
Page 101 of 316
February 25, 2011
The module reserves 1060 words for daily archives and 1440 words for hourly
archives. Because the default configuration sets the record size for 30 words, it
means that the maximum (default) number of archives per meter channel is 35
daily archives and 48 hourly archives. However, because you can change the
number of words per archive, the actual maximum number of archives per meter
channel will depend on the configured number of words per archive as follows:
Number of Words per
Archive
Number of Daily Archives
Number of Hourly Archives
10
106 daily archives
144 hourly archives
20
53 daily archives
72 hourly archives
30
35 daily archives
48 hourly archives
40
26 daily archives
36 hourly archives
You may also configure the accumulator type for each archive. You must
configure one of the following options:
Mass
Energy (Gas product only)
Net Volume
Gross Volume
Gross Standard
Water Volume (Liquid product only)
The following topics show the default archive structure when you configure a new
meter. You can edit this structure according to your own requirements.