beautypg.com

Table 3-1. power-up built-in test error codes, Power-up built-in test error codes -2 – KEPCO KLP Series User Manual, Rev 4 User Manual

Page 44

background image

3-2

KLP091313

• Status display flashes PROT for 2 seconds while DC VOLTS and DC AMPERES dis-

plays show previously stored OVP and OCP trigger levels. NOTE: to reprogram OVP
or OCP, refer to PAR. 3.2.11.

NOTE: To eliminate the display of model, virtual model, and protection levels on power-up,

refer to PAR. 3.2.17.2 for quick boot.

• For E-Series models, the LAN indicator blinks rapidly during initialization. If an IP

address is found, it stays on without blinking. If an IP address is not found, the LAN
indicator stays off.

• If any fault is configured for AUTO recovery (see PAR. 3.2.17.3.2), the status display

flashes AUTO for one second.

• If remote inhibit is active (see PAR. 3.2.6) upon power-up, the status display flashes

rINH for one second.

• If an error occurs, an error code is displayed in the status display (see Table 3-1).

3. After a successful self test, the default conditions upon power up are as follows:

• Status display shows SET.

• output is disabled (green DC OUTPUT indicator is off). If remote analog mode is

selected (PAR. 3.4), output is enabled unless Remote Inhibit, pin 8 of the Analog I/O
Connector (see Figure 2-2 and Table 2-7) is grounded.

DC VOLTS and DC AMPERES displays show programmed output conditions: either 0

Volts, minimum Amperes (see NOTE, PAR. 3.2.1) or, if DIP switch position 3 enabled
(see Table 2-2), previously saved setpoint values in effect upon power off.

TABLE 3-1. POWER-UP BUILT-IN TEST ERROR CODES

ERROR CODE

MEANING

E310

System Error

E313

Calibration Memory Error

E315

Configuration Memory Error

E341

Memory Error (CRC)

E330

Self Test Error

Ecal

Calibration Error - The unit will try to restore the previous calibration.

Eclp

Previous Calibration Error - After detecting a Calibration Error (Ecal) and trying to use
the previous calibration, an error was detected, and the unit will attempt to restore the
factory calibration.

Eclf

Factory Calibration Error - The unit has failed to restore the factory calibration after fail-
ing to restore the previous calibration. The unit will not operate after this error has
been displayed and must be referred for service.

NOTE: During power-up the power supply performs detailed software check sequences. If a failure is detected dur-
ing power-up, the DC VOLTS and DC AMPERES displays are blanked and the Status display shows an error code.
For errors that occur after power-up, refer to the Developer’s Guide for typical error codes and possible causes. For
these and all other error codes, refer to authorized service personnel if corrective action is required.

This manual is related to the following products: