PROGRAMMING CHARACTERISTICS - ANALOG

Analog remote control

selection Activate with jumper at analog program-

ming connector

Recognized during power up.

isolation Safety Extra Low Voltage (SELV)

Analog Input Update Rate

2Hz (0.5 Second) Applies to program-
ming by voltage/ resistance and read-
back specifications.

Analog input voltage digitized (12-bit
resolution), optically isolated, then pro-
cessed by digital section.

Programming by voltage

voltage 0-10V

See PAR. 4.3.3 to reduce Full Scale
voltage.

current 0-10V

Min. programming limit; see Table 1-2.
See PAR. 4.3.3 to reduce Full Scale
voltage.

Programming by resistance

voltage 0-10K ohms

See PAR. 4.3.3 to reduce Full Scale
resistance.

current 0-10K ohms

Min. programming limit; see Table 1-2.
See PAR. 4.3.3 to reduce Full Scale
resistance.

Readback

0-10V proportional signal

Proportional to analog control volt-
age/resistance.

Remote inhibit

TTL compatible

Dual polarity; see PAR. 3.2.17.3.1.

Composite status flag

Isolated form C contacts

Programmable functions (PAR.
3.2.17.1).

PROGRAMMING CHARACTERISTICS - DIGITAL

Supported Interfaces

standard models GPIB and RS 232

SCPI command set for GPIB and RS
232 (see KLP Developer’s Guide).

E-Series models GPIB and LAN

Support SCPI command set (see KLP
Developer’s Guide) for GPIB and LAN;
Support four interfaces for LAN:
1. Web interface, port 80 (LXI Class C,
Version 1.2
2. SCPI Telnet, port 5024
3. SCPI Sockets, port 5025
4. VXI 11, port 1024

GPIB

GPIB address range: 1 to 30

Factory default is 6.

RS 232

standard models Baud Rate range: 2400, 4800, 9600,

19,200 or 38,400

Factory default is 38,400.

Digital remote control

isolation Safety Extra Low Voltage (SELV)

format compatible with SCPI protocols

W98 SE and later operating systems.

Programming resolution

0.024% of Emax and Imax

Programming accuracy

0.05% of Emax and Imax

Readback resolution

0.024% of Emax and Imax

Readback accuracy

Either 0.1% of Emax and Imax, or front
panel voltmeter or ammeter display res-
olution, whichever is greater.(1)

±1 LSB error

Status reporting

OVP, OCP, OTP, output lead fault
(OLF), fan failure, power loss

See PAR. 1.5.4 and 1.5.9.

(1) Display resolution is determined by the number of significant digits shown, relative to the decimal point. Resolution is 10-X where
X is the number of digits to the right of the decimal point. E.g for display of 10.00V, resolution is 10-2 or 0.01 or 10mV; for display of
150.0A, resolution is 10-1 or 0.1 or 100mA.

TABLE 1-3. KLP SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION/COMMENT