KLP 091313

1-5

OUTPUT CHARACTERISTICS - CONTINUED

Transient recovery
for load change

excursion

1% of Emax

50% load step 2A/microsecond max.

recovery

2 msec

Return to 0.1% of setting.

Turnon/turnoff overshoot

2%

Rated output, any load

Rise Time

Voltage 10V, 20V, 36V: 30 msec, 75V: 40 msec,

150V: 50 msec, 300V: 60 msec,

600V: 75 msec

0 - Emax, rated load (resistive)

Current 10V, 20V, 36V: 30 msec, 75V: 40 msec,

150V: 50 msec, 300V: 60 msec

600V: 75 msec

0 - Imax, rated load (resistive)

Fall Time

Voltage no load

10V: 475 msec, 20V: 525 msec,

36V: 825 msec, 75V: 2820 msec,

150V: 4850 msec, 300V: 4400 msec,

600V: 3150 msec,

Emax - 0, no load (open circuit).

NOTE: For improved performance, see

RODC option (PAR. 1.3.1).

Voltage rated load 10V, 20V, 36V: 30 msec, 75V: 40 msec,

150V: 50 msec, 300V: 60 msec

600V: 75 msec

Emax - 0, rated load (resistive)

Current 10V, 20V, 36V: 30 msec, 75V: 40 msec,

150V: 50 msec, 300V: 60 msec

600V: 75 msec

Imax - 0, rated load (resistive)

Overvoltage protection

voltage

20-120% of Emax

Programmable; see PAR. 3.2.11.
Selectable Recovery Mode (see PAR.
3.2.17.3.2

Overcurrent protection

current

72-120% of Imax

Output Load wire protection

Shutdown

Selectable Recovery Mode (see PAR.
3.2.17.3.2

Parallel operation

Active load sharing within 5% of Io rated Up to 5 units, maximum.

GENERAL (ENVIRONMENTAL) SPECIFICATIONS

Temperature

operating

-10 to +50°C

Rated load.

+50°C to +70°C

Derate current 3% per °C from 50°C to
70°C.

storage

-40°C to +85°C

Overtemperature protection

Shutdown

See PAR. 3.2.17.3.2.

Cooling

3 internal d-c fans

exhaust to the rear

Humidity

0 to 95% RH

non-condensing

Shock

20g, 11msec +/- 50% half sine

non-operating

Vibration

5 -10 Hz

10mm double amplitude

3-axes, non-operating

10-55 Hz

2g

3-axes, non-operating

Altitude

sea level to 10000 ft.

0-3,000 ft: 100%, linear derating to 70%
of power at 10,000ft.

Loss of source power protection

Shutdown

Selectable Recovery Mode (see PAR.
3.2.17.3.2).

Overtemperature protection

Shutdown

Fan failure protection

Shutdown

TABLE 1-3. KLP SPECIFICATIONS (Continued)