KLP 091313
1-5
OUTPUT CHARACTERISTICS - CONTINUED
Transient recovery
for load change
excursion
1% of Emax
50% load step 2A/microsecond max.
recovery
2 msec
Return to 0.1% of setting.
Turnon/turnoff overshoot
2%
Rated output, any load
Rise Time
Voltage 10V, 20V, 36V: 30 msec, 75V: 40 msec,
150V: 50 msec, 300V: 60 msec,
600V: 75 msec
0 - Emax, rated load (resistive)
Current 10V, 20V, 36V: 30 msec, 75V: 40 msec,
150V: 50 msec, 300V: 60 msec
600V: 75 msec
0 - Imax, rated load (resistive)
Fall Time
Voltage no load
10V: 475 msec, 20V: 525 msec,
36V: 825 msec, 75V: 2820 msec,
150V: 4850 msec, 300V: 4400 msec,
600V: 3150 msec,
Emax - 0, no load (open circuit).
NOTE: For improved performance, see
RODC option (PAR. 1.3.1).
Voltage rated load 10V, 20V, 36V: 30 msec, 75V: 40 msec,
150V: 50 msec, 300V: 60 msec
600V: 75 msec
Emax - 0, rated load (resistive)
Current 10V, 20V, 36V: 30 msec, 75V: 40 msec,
150V: 50 msec, 300V: 60 msec
600V: 75 msec
Imax - 0, rated load (resistive)
Overvoltage protection
voltage
20-120% of Emax
Programmable; see PAR. 3.2.11.
Selectable Recovery Mode (see PAR.
3.2.17.3.2
Overcurrent protection
current
72-120% of Imax
Output Load wire protection
Shutdown
Selectable Recovery Mode (see PAR.
3.2.17.3.2
Parallel operation
Active load sharing within 5% of Io rated Up to 5 units, maximum.
GENERAL (ENVIRONMENTAL) SPECIFICATIONS
Temperature
operating
-10 to +50°C
Rated load.
+50°C to +70°C
Derate current 3% per °C from 50°C to
70°C.
storage
-40°C to +85°C
Overtemperature protection
Shutdown
See PAR. 3.2.17.3.2.
Cooling
3 internal d-c fans
exhaust to the rear
Humidity
0 to 95% RH
non-condensing
Shock
20g, 11msec +/- 50% half sine
non-operating
Vibration
5 -10 Hz
10mm double amplitude
3-axes, non-operating
10-55 Hz
2g
3-axes, non-operating
Altitude
sea level to 10000 ft.
0-3,000 ft: 100%, linear derating to 70%
of power at 10,000ft.
Loss of source power protection
Shutdown
Selectable Recovery Mode (see PAR.
3.2.17.3.2).
Overtemperature protection
Shutdown
Fan failure protection
Shutdown
TABLE 1-3. KLP SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION/COMMENT