To set harmonic amplitude, To set harmonic amplitude -4 – RIGOL DG4000 Series User Manual
Page 98
RIGOL Chapter 4 Harmonic Output
DG4000 Series User’s Guide
4-4
16 bits binary data is used to represent the output status of the 16 orders of
harmonics respectively, wherein, 1 represents enabling the output of the
corresponding harmonic and 0 represents disabling the output of the
corresponding harmonic. Users only need to use the numeric keyboard to
modify the value of each data bit (note: the leftmost bit representing
fundamental waveform is always X and can not be modified). For example, set
the 16 bits data to X001 0000 0000 0001, thus 4th and 16th orders of
harmonics are output.
Note: the actual harmonics output is determined by the “Order” currently
specified.
To Set Harmonic Amplitude
After entering the harmonic setting menu, press Ampl to set the amplitude of
each order of harmonic.
1. Sn: press this softkey to select the sequence number of the harmonic to be
set.
2. Ampl: press this softkey to set the amplitude of the harmonic selected. Use
the numeric keyboard or direction keys and knob to input the amplitude value
and then select the desired unit from the pop-up menu.
For the input method of amplitude value, refer to the introduction in
The amplitude units available are Vpp, mVpp, Vrms, mVrms and dBm (not
available in HighZ).