beautypg.com

To select modulating waveform source, To select modulating waveform source -15 – RIGOL DG4000 Series User Manual

Page 115

background image

Chapter 5 Modulated Waveform Output

RIGOL

DG4000 Series User’s Guide

5-15

Carrier Waveform

Frequency Range

Sine

1μHz to 160MHz

Square

1μHz to 50MHz

Ramp

1μHz to 4MHz

Arbitrary Waveform

1μHz to 40MHz


After the carrier waveform is selected, you can press Freq/Period to highlight
“Freq”, and then use the numeric keyboard or direction keys and knob to input the
desired frequency value.

To Select Modulating Waveform Source


Press ModSource to select “Int” or “Ext” modulating waveform source.

1. Internal Source

When internal source is selected, the modulating waveform is set as a Square
with 50% duty cycle, and the frequency at which the output frequency shifts
between “carrier frequency” and “hop frequency” is determined by “FSK Rate”.

2. External Source

When external source is selected, the generator accepts the external
modulating signal from the [Mod/FSK/Trig] connector at the rear panel.


Note: the [Mod/FSK/Trig] connector is different when controlling FSK
and AM/FM/PM modulations externally. In FSK modulation, the
[Mod/FSK/Trig] connector has adjustable edge polarity.

[Mod/FSK/Trig]