To Select Carrier Waveform Shape


OSK carrier waveform can only be sine waveform. Press Sine at the front panel.

To Set Carrier Frequency


After carrier waveform shape is selected, press Freq/Period to highlight “Freq”
and use the numeric keyboard or direction keys and knob to input the desired
frequency. The range is from 1μHz to 160MHz.

To Select Modulating Waveform Source


Press ModSource to select “Int” or “Ext” modulation source.

1. Internal Source

When internal source is selected, the modulating waveform is set as a Square
with 50% duty cycle. At this point, the intermittence time and oscillate time of
the output signal is determined by the OSK “Rate”.

2. External Source

When external source is selected, the generator accepts external modulating
signal from the [Mod/FSK/Trig] connector at the rear panel.