beautypg.com

To select arbitrary waveform, Built-in waveform, To select arbitrary waveform -4 – RIGOL DG4000 Series User Manual

Page 80: Built-in waveform -4

background image

RIGOL Chapter 3 Arbitrary Waveform Output

DG4000 Series User’s Guide

3-4

To Select Arbitrary Waveform


DG4000 allows users to select arbitrary waveforms stored in internal or external
memory for output. Press Arb, use

to open the 2/2 menu page, and then press

Select Wform to select “Builtin”, “Stored Wforms” or “Volatile Wform” for arbitrary
waveform output.

Built-In Waveform


Select from the 150 kinds of built-in arbitrary waveforms of DG4000 as shown in
the table below. Press BuiltIn and select a kind (“Common”, “Project”, “SectMod,
“Bioelect”, “Medical”, “Standard”, “Maths”, “Trigonome”, “Anti Trigonome” or
“Window”); the corresponding waveforms are displayed on the interface; use the
knob to select the desired waveform; use

to open the 2/2 menu page and

press Select to select the specified waveform.

Table 3-1 Built-in Waveform Table

Name

Explanation

Common
DC

DC signal

AbsSine

Absolute value of a Sine

AbsSineHalf

Absolute value of half a Sine

AmpALT

Gain oscillation curve

AttALT

Attenuation oscillation curve

GaussPulse

Gauss pulse

NegRamp

Negative ramp

NPulse

Negative pulse

PPulse

Positive pulse

SineTra

Sine-Tra waveform

SineVer

Sine-Ver waveform

StairDn

Stair-down waveform

StairUD

Stair-up and stair-down waveform

StairUp

Stair-up waveform

Trapezia

Trapezoid waveform

Project