3. Manual Trigger

A sweep will be generated from the corresponding channel once you press

Trigger1 or Trigger2 at the front panel.

Trigger Output Edge


In Sweep mode, when “Int” or “Manual” trigger source is selected, the generator
will output a TTL compatible signal with specified edge from the [Mod/FSK/Trig]
connector at the rear panel.

 Internal Trigger: the generator outputs a Square waveform with 50% duty

cycle from the [Mod/FSK/Trig] connector at the beginning of the Sweep.
The trigger period depends on the specified sweep time, return time, start
hold and end hold.

 Manual Trigger: the generator outputs a Pulse waveform with greater than

1μs pulse width at the beginning of the Sweep from the [Mod/FSK/Trig]
connector.

 External Trigger: the [Mod/FSK/Trig] connector is used as the input

terminal of external trigger signal and has no trigger output.


[Mod/FSK/Trig]

[Mod/FSK/Trig]