RIGOL Chapter 13 Specifications

DG4000 Series User’s Guide

13-8

Frequency Change

50ms

50ms

Amplitude Change

300ms

310ms

Select User Arb

500ms

510ms


Trigger Characteristics
Trigger Input

Level

TTL-compatible

Slope

Rising or falling (selectable)

Pulse Width

> 50ns

Latency

Sweep: <100ns (typical)
Burst: <300ns (typical)

Trigger Output
Level

TTL-compatible

Pulse Width

> 60ns (typical)

Maximum Rate

1MHz


Clock Reference
Phase Offset
Range

0° to 360°

Resolution

0.03°

External Reference Input
Lock Range

10MHz ± 50Hz

Level

250mVpp to 5Vpp

Lock Time

< 2s

Impedance (Typical)

1kΩ, AC coupling

Internal Reference Output
Frequency

10MHz ± 50Hz

Level

3.3Vpp

Impedance (Typical)

50Ω, AC coupling


Sync Output
Level

TTL-compatible

Impedance

50 Ω, nominal value


General Specifications