Example: Edit Block
The following example introduces how to use “Edit Block” to create an arbitrary
waveform fulfilling the following conditions.
Parameter
Value
Cycle Period
12μs
High VLimit
4V
Low VLimit
-2V
Interp
Linear
X1Y1
2, 4V
X2Y2
4, -2V
Operation Procedures:
1. Press Arb and use
to open the 2/2 menu page; then press Create New
Cycle Period, use the numeric keyboard to input “12” and select the unit
“μs” from the pop-up menu.
2. Press High VLimit, use the numeric keyboard to input “4” and select the unit
“V” from the pop-up menu.
3. Press Low VLimit, use the numeric keyboard to input “-2” and select the unit
“V” from the pop-up menu.
4. Press Init #Points, use the numeric keyboard to input “4” and press OK.
Note: at this point, a -2 V level line appears.
5. Press Interp to select “Linear”.
6. Press Edit Block to enter the “Edit Block” interface.
1) Press X1 and use the numeric keyboard to input “2”; then press Y1, use
the numeric keyboard to input “4” and select the unit “V” from the pop-up
menu. Use the same method to set X2 and Y2.