beautypg.com

C.1 standard iqpump drive specifications, Table c.3 common iqpump (p7u) drive specifications – Yaskawa iQpump Drive User Manual User Manual

Page 206

background image

206

YASKAWA

TM.iQp.01 iQpump Drive User Manual

C.1 Standard iQpump Drive Specifications

Table C.3 Common iQpump (P7U) Drive Specifications

Model Number

CIMR-P7U‰-107

Specification

Con

tr

o

l Charac

teris

tic

s

Control method

Sine wave PWM

V/f control

Speed range

40:1

Speed control accuracy

±2 to 3% (77

°F ± 50°F) (25°C ± 10°C)

Frequency accuracy
(temperature characteristics)

Digital references: ± 0.01% (14

°F to 104°F) (-10°C to +40°C)

Analog references: ±0.1% (77

°F ± 50°F) (25°C ±10°C)

Frequency setting resolution

Digital references: 0.01 Hz

Analog references: 0.025/50 Hz (10 bit with sign)

Frequency setting signal
(Speed Command)

0-10 Vdc, 4-20 mA

Acceleration/Deceleration time

0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings)

Main control functions

Restarting for momentary power loss, bi-directional speed search, overtorque detection, 5 preset speeds,

acceleration/deceleration time changes, S-curve acceleration, 3-wire sequence, auto-tuning, cooling fan ON/OFF control, torque compensation, jump

frequencies, upper and lower limits for frequency references, DC braking for starting and stopping, high-slip braking, PI control (with sleep function),

energy-saving control, Modbus communications (RS-485/422, 19.2 kbps maximum), fault reset, and copy function

Pr

ote

c

tive Fu

nct

ions

Motor protection

Protection by electronic thermal overload relay

Fuse blown protection

Stops for fuse blown

Overload capacity and maximum
current

110% of rated output current for 60 seconds

Overvoltage protection

208-240 VAC: Stops when main-circuit DC voltage is above 410V

480 VAC: Stops when main-circuit DC voltage is above 820V

Undervoltage protection

208-240 VAC: Stops when main-circuit DC voltage is below 190V

480 VAC: Stops when main-circuit DC voltage is below 380V

Momentary power loss ridethru

Power Interruptions of 15 ms or more

By selecting the momentary power loss method, operation can be continued if power is restored within 2sec

Cooling fin overheating

Protection by thermistor

Stall prevention

Stall prevention during acceleration, deceleration, or running

Grounding protection

Protection by electronic circuits. (50% of inverter rated current)

Charge indicator

Lit when the main circuit DC voltage is approx. 50 Vdc or more

Enclosure Type

Enclosed wall-mounted type (NEMA 1): CIMR-P7U20P4 thru 2030 and 40P4 thru 4055

Open chassis type (IP00): CIMR-P7U2022 thru 2110 and 4030 thru 4300

Envir

onm

en

t

Ambient operating temperature

14

°F to 104°F (-10°C to 40°C) NEMA 1 type

14

°F to 113°F (–10°C to 45°C) Open chassis type

Ambient operating humidity

95% max. (with no condensation)

Storage temperature

-4

°F to 140°F (- 20°C to + 60°C) short-term temperature during transportation

Application site

Indoor (no corrosive gas, dust, etc.)

Altitude

3300 ft. (1000 m), higher altitudes by derate

Vibration

10 to 20 Hz, 32 ft/sec

2

(9.8 m/s

2

) max.; 20 to 50 Hz, 6.5 ft/sec

2

(2 m/s

2

) max.

Approval Agencies

UL File E143427